| Flow
Computers |

Multi-Function
Flow Totalizer, Ratemeter and Batcher
- "EZ
Setup" Guided Setup for First Time Users
- Multiple
Instrument Functions
- Menu
Selectable Hardware & Software Features
- Two
Line LCD or VFD Display
- Universal
Viscosity Curve (UVC) and API Eq.
- Advanced
Batching Features: Overrun Compensation,
Autobatch Start, Print End of Batch
- Isolated
Outputs Standard
- RS-232
Port Standard, RS-485 Optional
- DIN
Enclosure with Two Piece Connectors
- Windows TM
Setup Software
- On
Board Data Logging
- DDE
Server & HMI Software Available
|
The SUPERtrol-I Flow Computer satisfies the instrument
requirements for a variety of flowmeter types in liquid
applications. Multiple flow equations and instrument functions
are available in a single unit with many advanced features.
The alphanumeric display shows measured and calculated
parameters in easy to understand format. Single key direct
access to measurements and display scrolling is supported
The versatility of the SUPERtrol-I permits a wide measure of
versatility within the instrument package. The various
hardware inputs and outputs can be “soft” assigned to meet
a variety of common application needs. The user “soft
selects” the usage of each input/output while configuring
the instrument.
The isolated analog output can be chosen to follow volume
flow, corrected volume flow, mass flow, temperature, or
density by means of a menu selection. Most hardware features
are assignable by this method.
The user can assign the standard RS-232 Serial Port for data
logging, transaction printing, or for connection to a modem
for remote meter reading.
A Service or Test mode is provided to assist the user during
start-up system check out by monitoring inputs and exercising
outputs and printing system setup.
|

Multi-Function
Flow Computer
- Custody
Transfer with Audit Trail
- Liquid,
Gas, Steam and Heat Flow Equations
- Menu
Selectable Hardware & Software Features
- Two
Line LCD or VFD Display
- Foreign
Language Options
- Isolated
Pulse and Analog Outputs Standard
- RS-232
Port Standard, RS-485 Optional
- Enclosure
Options: Panel, Wall, Explosion Proof
- WindowsTM Setup
Software
- NX19
Gas Equations
- DDE
Server & HMI Software Available
|
The SUPERtrol II Flow Computer satisfies the instrument
requirements for a variety of flowmeter types in liquid, gas,
steam and heat applications. Multiple flow equations are
available in a single instrument with many advanced features.
The alphanumeric display offers measured parameters in easy to
understand format. Manual access to measurements and display
scrolling is supported
The versatility of the Flow Computer permits a wide measure of
versatility within the instrument package. The various
hardware inputs and outputs can be “soft” assigned to meet
a variety of common application needs. The user “soft
selects” the usage of each input/output while configuring
the instrument. Consider the following illustrative examples.
The isolated analog output can be chosen to follow the volume
flow, corrected volume flow, mass flow, temperature, pressure,
or density by means of a menu selection. Most hardware
features are assignable by this method.
The user can assign the standard RS-232 Serial Port for
external data logging, transaction printing, or for connection
to a modem for remote meter reading.
A Service or Test mode is provided to assist the user during
start-up system check out by monitoring inputs and exercising
outputs. The system setup can also be printed.
|
Mass
Flow Computer
- Compensates
Steam, Gases and Liquids for
Temperature and Pressure to Yield Corrected
Volume, Mass and Heat Flow.
- Two
Line by 20 Character Super Twist BackLit
LCD Display
- Square
Root Extraction of DP Inputs
- 16
Point Linearization
- Displays
Compensated Rate and Total Flow
- Takes
a Direct 100 W Platinum RTD
- Flow
Rate, Temperature and Pressure Alarms
- 4-20
mA and Pulse Output Based on Compensated
Flow
- Non-volatile
Memory
- 24
Volt Excitation Provided
- Front
Panel NEMA 4X/IP 65 Rated
|
The KEP MASStrol is a microprocessor based instrument designed
to measure compensated flow in an industrial environment.
Three analog inputs for temperature, pressure and flow are
provided to measure the parameters needed to calculate the
actual compensated mass, volume or heat flow.
Special signal conditioning circuitry
is included to allow direct connection of platinum resistance
temperature detectors (RTD’S). A high speed digital input is
provided to interface with pulse output type flowmeters. As an
alternative, voltage inputs or current loops can be used for
the above.
All instrument interface is with a 32
point screw terminal strip on the rear of the instrument.
|
Differential
Pressure Flow Computer
- Compensates
Steam, Gases and Liquids for
Temperature and Pressure to Yield Corrected
Volume, Mass and Heat Flow.
- Two
Line by 20 Character Super Twist BackLit
LCD Display
- Accepts
Dual DP Inputs
- Square
Root Extraction of DP Inputs
- 16
Point Linearization
- Displays
Compensated Rate and Total Flow
- Takes
a Direct 100 W Platinum RTD
- Flow
Rate, Temperature and Pressure Alarms
- 4-20
mA and Pulse Output Based on Compensated
Flow
- 24
Volt Excitation Provided
- Front
Panel NEMA 4X/IP 65 Rated
|
The KEP DPFC is a microprocessor based instrument designed to
measure compensated flow in an industrial environment. Four
analog inputs for temperature, pressure and dual differential
pressure are provided to measure the parameters needed to
calculate the actual compensated volume, mass or heat flow.
Special signal conditioning circuitry
is included to allow direct connection of platinum resistance
temperature detectors (RTD’S). Voltage inputs or current
loops can be used for the above.
All instrument interface is with a 32
point screw terminal strip on the rear of the instrument.
|
|
|
|