Flow Computers
 
 
SUPERtrol I
 


Multi-Function Flow Totalizer, Ratemeter and Batcher

Features
Description

 

  • "EZ Setup" Guided Setup for First Time Users
  • Multiple Instrument Functions
  • Menu Selectable Hardware & Software Features
  • Two Line LCD or VFD Display
  • Universal Viscosity Curve (UVC) and API Eq.
  • Advanced Batching Features: Overrun Compensation,
    Autobatch Start, Print End of Batch
  • Isolated Outputs Standard
  • RS-232 Port Standard, RS-485 Optional
  • DIN Enclosure with Two Piece Connectors
  • Windows&nbspTM Setup Software
  • On Board Data Logging
  • DDE Server & HMI Software Available

The SUPERtrol-I Flow Computer satisfies the instrument requirements for a variety of flowmeter types in liquid applications. Multiple flow equations and instrument functions are available in a single unit with many advanced features.

The alphanumeric display shows measured and calculated parameters in easy to understand format. Single key direct access to measurements and display scrolling is supported

The versatility of the SUPERtrol-I permits a wide measure of versatility within the instrument package. The various hardware inputs and outputs can be “soft” assigned to meet a variety of common application needs. The user “soft selects” the usage of each input/output while configuring the instrument.

The isolated analog output can be chosen to follow volume flow, corrected volume flow, mass flow, temperature, or density by means of a menu selection. Most hardware features are assignable by this method.

The user can assign the standard RS-232 Serial Port for data logging, transaction printing, or for connection to a modem for remote meter reading.

A Service or Test mode is provided to assist the user during start-up system check out by monitoring inputs and exercising outputs and printing system setup.

SUPERtrol I Data Sheet
(Size 55 Kilobytes)

 



 
SUPERtrol II
 


Multi-Function Flow Computer
Features Description

 

  • Custody Transfer with Audit Trail
  • Liquid, Gas, Steam and Heat Flow Equations
  • Menu Selectable Hardware & Software Features
  • Two Line LCD or VFD Display
  • Foreign Language Options
  • Isolated Pulse and Analog Outputs Standard
  • RS-232 Port Standard, RS-485 Optional
  • Enclosure Options: Panel, Wall, Explosion Proof
  • WindowsTM Setup Software
  • NX19 Gas Equations
  • DDE Server & HMI Software Available
The SUPERtrol II Flow Computer satisfies the instrument requirements for a variety of flowmeter types in liquid, gas, steam and heat applications. Multiple flow equations are available in a single instrument with many advanced features.

The alphanumeric display offers measured parameters in easy to understand format. Manual access to measurements and display scrolling is supported

The versatility of the Flow Computer permits a wide measure of versatility within the instrument package. The various hardware inputs and outputs can be “soft” assigned to meet a variety of common application needs. The user “soft selects” the usage of each input/output while configuring the instrument. Consider the following illustrative examples.

The isolated analog output can be chosen to follow the volume flow, corrected volume flow, mass flow, temperature, pressure, or density by means of a menu selection. Most hardware features are assignable by this method.

The user can assign the standard RS-232 Serial Port for external data logging, transaction printing, or for connection to a modem for remote meter reading.

A Service or Test mode is provided to assist the user during start-up system check out by monitoring inputs and exercising outputs. The system setup can also be printed.

SUPERtrol II Data Sheet
(Size 55 Kilobytes)

 



 
MASStrol
 

Mass Flow Computer

Features Description

 

  • Compensates Steam, Gases and Liquids for
    Temperature and Pressure to Yield Corrected
    Volume, Mass and Heat Flow.
  • Two Line by 20 Character Super Twist BackLit
    LCD Display
  • Square Root Extraction of DP Inputs
  • 16 Point Linearization
  • Displays Compensated Rate and Total Flow
  • Takes a Direct 100 W Platinum RTD
  • Flow Rate, Temperature and Pressure Alarms
  • 4-20 mA and Pulse Output Based on Compensated
    Flow
  • Non-volatile Memory
  • 24 Volt Excitation Provided
  • Front Panel NEMA 4X/IP 65 Rated
The KEP MASStrol is a microprocessor based instrument designed to measure compensated flow in an industrial environment. Three analog inputs for temperature, pressure and flow are provided to measure the parameters needed to calculate the actual compensated mass, volume or heat flow.
     Special signal conditioning circuitry is included to allow direct connection of platinum resistance temperature detectors (RTD’S). A high speed digital input is provided to interface with pulse output type flowmeters. As an alternative, voltage inputs or current loops can be used for the above.
     All instrument interface is with a 32 point screw terminal strip on the rear of the instrument.

MASStrol Data Sheet
(Size 47 Kilobytes)

 



 
DPFC
 

Differential Pressure Flow Computer
Features Description

 

  • Compensates Steam, Gases and Liquids for
    Temperature and Pressure to Yield Corrected
    Volume, Mass and Heat Flow.
  • Two Line by 20 Character Super Twist BackLit
    LCD Display
  • Accepts Dual DP Inputs
  • Square Root Extraction of DP Inputs
  • 16 Point Linearization
  • Displays Compensated Rate and Total Flow
  • Takes a Direct 100 W Platinum RTD
  • Flow Rate, Temperature and Pressure Alarms
  • 4-20 mA and Pulse Output Based on Compensated
    Flow
  • 24 Volt Excitation Provided
  • Front Panel NEMA 4X/IP 65 Rated
The KEP DPFC is a microprocessor based instrument designed to measure compensated flow in an industrial environment. Four analog inputs for temperature, pressure and dual differential pressure are provided to measure the parameters needed to calculate the actual compensated volume, mass or heat flow.
     Special signal conditioning circuitry is included to allow direct connection of platinum resistance temperature detectors (RTD’S). Voltage inputs or current loops can be used for the above.
     All instrument interface is with a 32 point screw terminal strip on the rear of the instrument.

DPFC Data Sheet